NMD90 Copper
Two or three copper conductors with 90°C PVC Nylon insulation or XLPE (RW90) insulation. Bare bonding wire and overall jacket of moisture resistant and flame retardant PVC, with FT1 rating. Rated 300 Volts.
Applications
- For open or concealed wiring in dry locations where not exposed to mechanical injury.
- Maximum conductor temperature 90°C.
- Approved for use with ceiling fixtures.

Specifications & Compliances
- CSA C22.2 No. 48-M90
- 14awg white 2C and 3C 14awg for general application
- 14awg blue 2C for bedroom outlets terminating at AFCI (Arc Fault Circuit Interrupters)
- Red 2C for 220 Volts circuit
- 12awg white, red or yellow
- 10awg white or orange
- 8awg 3C white, 2C red twisted construction
- 6awg 3C white, 2C red twisted construction
Insulation colours:
- 2C – black, white
- 3C – black, white, red